CSA approval Constant Temperature Water Heater Control Board BW-HK002R
what is water heater control board
The water heater control panel is an important part of the entire water heater, so it is important that you take care of it regularly so that the water heater lasts a long time. Water heater control panels are temperature control panels, water heater firing control panels, or water heater valve control panels.
here is the Water Heater Control Board
Function description | |
1) It works with a display. | |
2) It works with a ventilator. | |
3) It works with a on-off valve, a proportional valve and a section valve. | |
4) It is with a buzzer. | |
5) It has AC ionization flame signal detection. | |
6) Status keeping function: If the nP menu was set as ON, after power on again, the system will return to the last status before the power is cut off. |
|
7) Flue pipe block-up protection. | |
8) Malfunction protection and warning function. | |
9) Compliance with Standard: BS EN298: 2012. ANSI Z21.20 -2014. CAN/CSA C22.2 No. 60730-2-5-2014. | |
Main technical parameters |
|
Working voltage range | 90VAC ~ 120VAC |
Rated voltage | 120VAC 60Hz |
Power frequency | 50/60Hz±5% |
Rated frequency | 50Hz |
Dielectric strength(V/1min) | 1800V, 0.5mA, 3S |
Working ambient temperature | -10℃~70℃ |
Ambient temperature | -20℃~70℃ |
Life cycle | ≥50,000 times |
Temperature setting range | 35-65℃ |
High temperature protection | when the output water temperature ≥85℃ for 3S |
Pre- cleaning time | 2S |
After cleaning time | 20s |
Start-up water flow | ≤3L/min |
Closing water flow | ≤2.5L/min |
Ignition time | 8±1S |
Cleaning time before 2nd ignition | 3S |
Max. allowable No. of ignition | 2 |
Valve moving pulse | 0.5±0.05S |
24V Valve open voltage | ≥24V |
24V Valve holding voltage | ≥8.5V |
Output voltage of switch power supply | 5VDC (with 300mA working current) |
30±1.5VDC(with 510mA working current) | |
12±1VDC(with 110mA working current) | |
Ion sensibility of flame detection | ≥5.1MΩ |
Temperature detection precision | ±2℃ |
Waiting time of reaching setted temperature | ≤35S |
Water temperature overshoot range | ±3℃ |
Timing tolerance | ±1 minutes |
Post-purge time | 20±2s |
Time to achieve safe shut down | <1s |
Trial for ignition period | 7.5±1s |
how to replace a water heater control board
The water heater control board is not recommended to be removed and replaced by the user.
If you wish to replace the water heater control board yourself, turn off the gas or disconnect the power supply, identify its components, disconnect the line to the water heater control board using an open-end spanner or adjustable spanner and bring the original water heater control board to a hardware or gas supply Reconnect the new water heater control board in reverse order.
View More